Wireless Monitoring System

Long-range radio data acquisition systems (LS Series) constitute a new tool in the geotechnical and structural monitoring world.  

The LS systems help users:

  • Better manage their structure or project by providing data from the instruments of their choice;
  • Improve the protection of large structure by connecting large arrays of instruments;
  • Lower costs by connecting instruments over long distances without the need for cabling.
Contact us at 1 450 441-5444 to inquire with our team of consultants or complete a request.

Battery life

Up to 10 years

Data storage

Each node can store up to 200,000 readings.
The gateway has 8 Gb of on-board memory.

Radio range

Up to 15 km

Temperature range

-40 to 50 °C

Environmental protection rating

IP67

Compatible instruments

Vibrating wire instruments (1- and 5-channel options)

Analog instruments (4 channels)

  • Thermistors
  • RTDs
  • Bridge Strain gages
  • Thermocouples
  • Potentiometers
  • ±10 V
  • 4-20 mA

Vibrating wire Node

Excitation voltage: ±5 V   
Measurement range: 300 to 7000 Hz
Resolution (-40 to 85 °C): 0.12 Hz
Accuracy (-40 to 85 °C): 0.018% FS

Thermistor

Measurement range: 0 Ω to 4 M Ω
Resolution: 1 Ω
Accuracy (20 °C): 0.05 °C

Barometer

Pressure range: 300 to 1100 hPa

Tiltmeter Node

Type: MEMS (Micro-Electro-Mechanical System)
Inclinometer Range:  ±15°
Accuracy (±5°): 0.004°
Accuracy (±15°): 0.025°
Resolution: 0.001°
Repeatability: 0.005°
Axes: Biaxial
Temperature sensor resolution: 0.1 °C
Temperature sensor accuracy: ±0.5 °C

Analog node

Power supply: 5 V DC / 12 V DC / 24 V DC up to 60 mA selectable for each channel

Voltage

Measuring ranges [V DC]: ±10; ±1.25
Accuracy (-40 to 85 °C): ±0.05% FS

Current loop (2-3 wires)

Measuring range: 4-20 mA
Accuracy (0 to 50 °C): 0.05% FS

Potentiometer

Accuracy (0 to 50°C): ±0.02% FS

Full wheatstone bridge

Accuracy (0 to -50 °C): ±0.1% FS

Thermistor

Accuracy (0 to 50 °C): ±0.2 °C

PT 100

Accuracy (20 °C): ±0.8 °C